Desertcart purchases this item on your behalf and handles shipping, customs, and support to USA.
๐ฅ Donโt get locked outโupgrade your HVACโs safety sensor today! ๐ก๏ธ
The Rheem SP20172 Flammable Vapor Sensor Kit is a genuine OEM replacement part designed to detect hazardous vapors and prevent HVAC lockouts. Compact and easy to install, it restores your systemโs safety and functionality quickly, saving you from expensive repairs and downtime.
| ASIN | B00G2DL8M8 |
| Best Sellers Rank | #21,626 in Tools & Home Improvement ( See Top 100 in Tools & Home Improvement ) #15 in Water Heater Replacement Parts |
| Brand | Rheem |
| Brand Name | Rheem |
| Customer Reviews | 4.7 out of 5 stars 3,048 Reviews |
| Global Trade Identification Number | 00020352574103 |
| Item Dimensions | 6.7 x 2.7 x 9.4 inches |
| Item Part Number | SP20172 |
| Item Type Name | FV Sensor Kit |
| Item Weight | 0.27 g |
| Item dimensions L x W x H | 6.7 x 2.7 x 9.4 inches |
| Manufacturer | Rheem |
| Material | Plastic |
| Material Type | Plastic |
| Model | SP20172 |
| Mounting Type | Flange Mount |
| Number of Items | 1 |
| Number of Packs | 1 |
| Output Type | Digital |
| Part Number | SP20172 |
| Specific Uses For Product | HVAC system maintenance and repair |
| Style | Modern |
| Style Name | Modern |
| UPC | 662766396171 020352574103 785971458424 |
| Unit Count | 1 Count |
| Upper Temperature Rating | 122 ยฐF |
M**C
The Genuine Rheem One - Fixed the Flammable Vapor Lockout Error on My Rheem Water Heater
I've had two identical Rheem Platinum 50-gallon water heaters for almost 10 years. Every few years it seems, they shut down and throw a "Flammable Vapor Lockout" error, which is indicated by seven flashes of the blue light on the gas valve assembly. A reset of the unit will usually clear the code. However, when the error starts happening too frequently for my taste, it's time to replace the flammable vapor sensor. This time, I checked the old sensor with a voltage-ohm meter and got a reading of 97,000 ohms resistance. According to Google, the reading should be between 9,000 and 45,000 ohms. So, mine was definitely reading outside the acceptable range, which indicates a failure. I used to contact Rheem and wait several days for them to send me a new vapor sensor under warranty for me to install myself. But, the last two times I just bit the bullet and ordered the sensor on Amazon. For less than $30 (as of 2026) I can have my water heater back up and running within two days (thanks to Amazon's 2-day shipping). The actual brand name of these sensors is ProTech. It's a brand apparently owned by Rheem. So, you're getting the official genuine Rheem part when you order this one. There are at least two cheaper but viable replacement sensors available on Amazon as I write this. One of them is half the price of the Rheem sensor. But I don't recognize the brand names and much prefer the OEM Rheem brand when safety is involved. The new sensor has worked flawlessly since I installed it two weeks ago. Installation takes less than 10 minutes. I'll continue to buy these as long as necessary, rather than bother with the water heater warranty.
J**.
Fixed FVS Fault after had hardwood floors refinished
This piece saved me a likely $150+ HVAC bill. One of my best purchases on here. I had my hardwood floors refinished and after I was able to return back my hot water heater wasn't working. I checked the controller unit and the flashing lights indicated I had a FVS Fault. I thought "well S***". (Appreantly the strong vapers from polyurethane sealant with hardwood refinishing can set this sensor off). I did a little research and decided to try and diy it. So glad I did. Installation was easy. Just a simple plug and play item. Then I reset my gas control unit and it worked instantly. Saved so much money and only took maybe 4 minutes. Works perfectly with my Rheem 50gal Professional Unit.
D**E
Perfect
Perfect replacement for our water heater. Easy install.
A**R
Good quality for cost
Easy fix for my reem water heater. at a reasonable cost if you have a littel bet of know how
U**S
Works well
The replacement FV Sensor works fine on my 2012 Whirlpool gas water heater. This is the second time I purchased the same Protech part from Amazon. The first Protech replacement FV Sensor lasted four years. The original factory installed FV Sensor lasted ten years. Four stars for the comparatively short life cycle. The dimensions in the product title description refer to the plastic bag the sensor comes in. The sensors are easy to install, no tools required.
S**8
Sensor works on my Bradford White hot water heater with Honeywell gas valve!
I saw "Otto's Gang" post, and he thought what mattered was the gas valve as far as a compatible sensor, and his picture was the exact same valve on my Bradford White hot water heater, so I bought this sensor. While mine does not mount like the Rheem water heater, the sensor itself looked exactly the same, although there is a different part number stamped on it (I'm guessing because it's a different mount). My water heater has a black strap that clips to hold the sensor below the controller. This sensor was way cheaper than the one listed specifically for Bradford White, and it arrived really quickly where the other one was days for delivery. I'd definitely buy this sensor again; forget paying 5 times the amount for the same sensor with a different part number printed on it! Also, I ohmed it and kept getting different readings, I never got a 0 reading, while my old sensor did return a 0 reading. Thanks so much to Otto's Gang for the helpful review and the sensor seller for offering this value for money!
F**X
Reset your controller!
after removing your old sensor, your controller's status might change, e.g. "Flammable vapor sensor lockout" might become "FVS fault detected." if you have a multimeter, use it to verify that your old sensor does not satisfy the resistance requirement. (based on service bulletins i found, the acceptable range is 13-45kฮฉ). otherwise, you may assume that your controller is correctly reporting sensor status. cheap, aftermarket sensors are tempting but they are sketchy. after buying one that was DOA, i bought a *used* Rheem sensor from Amazon Resale. i think these sensors are often returned by people who neglect to reset their controllers. if you have a multimeter, use it to verify that the new sensor satisfies the resistance requirement. (mine measured 16.8kฮฉ.) otherwise, just install it. to facilitate returning this sensor: install the cap/plug and run the wires through it before connecting the sensor *without* completing sensor-cap/plug assembly. at this point, your controller will act as though this sensor is defective. the installation instructions (dated 01/09) describe how to reset older controllers, so you might have to find instructions for *your* controller. there are online videos ... with any luck, you'll hear gas burning soon :-)
K**T
Amazon to the rescue. Hot water has been restored.
Let me start by saying "IT WORKED"!! This is important because at 11pm on a Thursday (before Memorial Day no less) my daughter discovered the hot water heater had quit working the hard way. She had to rinse off in ice cold tap water. I diagnosed the problem and had the part on order through Amazon by midnight for expedited delivery on Saturday. Friday, with no hot water was not great for the whole family. Saturday, the part arrived, I installed it and viola! Hot Water. My Richmond water heater, only about 3 years old, was indicating a FVS Lockout on the Honeywell Controller. FVS is the Flammable Vapor Sensor, something common to pilotless models to make sure there are no leaks before igniting. That is a good thing when it functions right. Its also a good thing when it fails that it prevents operation. Well, except for the cold showers, its a good thing. This set comes with the housing around the actual sensor. Why, because you can remove the old housing from the water heater itself, but the way the FVS installs in the housing you would destroy the housing removing the defective FVS. So the housing is there for a reason. The same thing for the tie wrap. You'll need to remove your wiring harness from the control unit, then carefully use pliers to pull the wire connectors from the defective FVS. I installed the harness first because I wanted to be careful to connect to the right terminals. I don't know that it matters, but I did not want to take a chance (two days without hot water if you recall). I carefully feed the harness through the housing and easily snapped the FVS in place. The chamfer on the edge of the FVS should allow easy insertion, but the blade (terminal) side goes into the housing FIRST. The part numbers were not an exact match, but cross checking indicated this to be a new replacement for my defective one. Hopefully the part number difference indicates a new and improved part. These things seem to have reliability issues. I guess over three years to savings in natural gas was worth it. Finally, I checked Amazon for this part in desperation. No one locally had it in stock. I could order the it might arrive the Tuesday or Wednesday after Memorial Day, leaving us without hot water for nearly a week. Thankfully Amazon exists and has priority shipping. No matter what a certain world "leader" thinks, Amazon exists due to this extreme level of customer service. If brick-and-mortar stores would actually take customer needs and service seriously, they would not have these problems. I prefer to buy local when I can. No hot water makes expedient service all the more important.
Z**N
Cheap Alternative
This is a great product! It was very easy to replace and works perfectly. Best of all, itโs much more affordable than the same item listed on Rheemโs website. Just make sure to check with a professional to ensure proper installation. Not responsible for any misuse. Highly recommend if youโre looking for a reliable and cost-effective option.
A**Z
Producto Rheem
Muy buen producto y dificil de conseguir pero en Amazon lo encontre inmediatamente y a un excelente precio comparado con otros proveedores
F**.
Rheem SP20172 Flammable Vapor Sensor Kit replacement went well
My Rheem water heater showed an error "Flammable Vapor Lockout" after close to 11 year service. Resetting procedure didn't clear the error and there was no gas smell at all. Checked resistance across FV sensor terminals and got 120 Kohm which was way above normal range 10-40 Kohm. This new Rheem SP20172 Flammable Vapor FV Sensor kit has 22Kohm resistance, after replacing the sensor kit, the water heater returned to normal operation again - good. Amazon overnight delivery was great, so that my Rheem heater was only down for one night.
M**H
Does what it's supposed to
I bought one locally a few years ago for over 3x this price. Worked fine, easy to install even if you have no idea what you're doing, if you can plug an appliance into the wall you can install this. All you need is a flathead screwdriver to pry the old one off (you could use a butterknife also) Reminder than most tanks require a reset after installing so if you plug it in and its still giving you an error just initiate a tank reset. (Can check google for how to do so)
A**O
solve my problem
works perfect
Trustpilot
1 month ago
1 month ago